Nsm-1003, Nsm-1004, Nsm-1005 – Dell POWEREDGE M1000E User Manual
Page 656: Nsm-1006

634
Fabric OS Message Reference
53-1002749-01
NSM-1003
5
NSM-1003
Message
Interface
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the specified interface has gone offline because the link is down.
Recommended
Action
Check whether the connectivity between the peer ports is proper, and the remote link is up using the
show interface command.
NSM-1004
Message
Interface
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the specified logical interface has been created.
Recommended
Action
No action is required.
NSM-1005
Message
The FCoE VLAN:
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the specified Fibre Channel over Ethernet (FCoE) VLAN is used in the FCoE daemon
(fcoed) and therefore cannot be disabled.
Recommended
Action
Remove all the FCoE sessions from the FCoE VLAN member ports and then disable the FCoE VLAN.
NSM-1006
Message
FCoE on VLAN:
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that FCoE has been disabled on the specified VLAN.