Fabric OS Message Reference

451

53-1002749-01

FW-1118

5

Recommended

Action

Verify that the cable is properly connected at both ends. Verify that the small form-factor pluggables
(SFPs) have not become faulty. An inexplicable fabric reconfiguration might be a transient error and
might not require troubleshooting.

FW-1118

Message

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the number of fabric reconfigurations has fallen below the low boundary. The following
occurrences can cause a fabric reconfiguration:

Two switches with the same domain ID have connected to one another.

Two fabrics have joined.

An E_Port has gone offline.

A principal link has segmented from the fabric.

A low number of fabric reconfigurations means that the fabric is functioning normally.

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation.

FW-1119

Message

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the number of fabric reconfigurations has risen above the high boundary. The following
occurrences can cause a fabric reconfiguration:

Two switches with the same domain ID have connected to one another.

Two fabrics have joined.

An E_Port has gone offline.

A principal link has segmented from the fabric.

Recommended

Action

Verify that all inter-switch link (ISL) cables are properly connected at both ends. Verify that the small
form-factor pluggable (SFP) has not become faulty. An inexplicable fabric reconfiguration might be a
transient error and might not require troubleshooting.