Fspf-1008, Fspf-1009, Fspf-1010 – Dell POWEREDGE M1000E User Manual
Page 452: Fspf-1011

430
Fabric OS Message Reference
53-1002749-01
FSPF-1008
5
FSPF-1008
Message
ICL triangular topology is formed among the domains:
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the inter-chassis link (ICL) triangular topology is formed.
Recommended
Action
No action is required.
FSPF-1009
Message
16G ICL topology is not recommended on local domain
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the current 16 Gbps inter-chassis link (ICL) topology is not recommended.
Recommended
Action
Use the switchShow, islShow, and lsdbShow commands to identify the neighbor domains that violate
the ICL connectivity requirement.
FSPF-1010
Message
ICL Topology is valid on local domain
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the current inter-chassis link (ICL) topology is valid for routing from the local switch.
Recommended
Action
No action is required.
FSPF-1011
Message
16G ICL topology is unbalanced.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the current configuration of inter-chassis link (ICL) paths are unbalanced.