Fabric OS Message Reference
459
53-1002749-01
FW-1140
5
FW-1140
Message
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the number of small form-factor pluggable (SFP) state changes has changed from a value
outside of the acceptable range to a value within the acceptable range. SFP state changes occur when
the SFP is inserted or removed.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation.
FW-1160
Message
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the number of link failures that the port experiences has changed. Link loss errors occur
when a link experiences a loss of signal and fails. Both physical and hardware problems can cause link
loss errors. Link loss errors frequently occur due to a loss of synchronization.
Recommended
Action
Check both ends of your cable connection. Verify that the cable and small form-factor pluggables (SFPs)
are not faulty.
Losses of synchronization commonly causes link failures. If you receive concurrent loss of
synchronization errors, troubleshoot the loss of synchronization.
FW-1161
Message
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the number of link failures that the port experiences has fallen below the low boundary.
Link loss errors occur when a link experiences a loss of signal and fails. Both physical and hardware
problems can cause link loss errors. Link loss errors frequently occur due to a loss of synchronization.
Check for concurrent loss of synchronization errors and, if applicable, troubleshoot them. A low number
of link loss errors means that the switch is functioning normally.
Recommended
Action
Check for concurrent loss of synchronization errors and, if applicable, troubleshoot them. Respond to this