Fcr-1081, Fcr-1082, Fcr-1083 – Dell POWEREDGE M1000E User Manual
Page 390

368
Fabric OS Message Reference
53-1002749-01
FCR-1081
5
FCR-1081
Message
The pause message is rejected by the domain
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that during the Coordinated HotCode protocol, a switch in the fabric has rejected the pause
message which prevented the protocol from completing. Any data traffic disruption observed during the
firmware download may have been the result of the rejected pause message.
Recommended
Action
No action is required.
FCR-1082
Message
The pause retry count is exhausted for the domain
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that during the Coordinated HotCode protocol, a switch in the fabric did not accept the pause
message which prevented the protocol from completing. Any data traffic disruption observed during the
firmware download may have been the result of this issue.
Recommended
Action
No action is required.
FCR-1083
Message
The resume message is rejected by the domain
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that during the Coordinated HotCode protocol, a switch in the fabric has rejected the pause
message which prevented the protocol from completing. Any data traffic disruption observed during the
firmware download may have been the result of the rejected resume message.
Recommended
Action
No action is required.