Fabric OS Message Reference
705
53-1002749-01
SEC-1075
5
SEC-1075
Message
Fail to
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates a corruption occurred during the distribution of the security database. This can only occur when
the primary fabric configuration server (FCS) distributes the security database to the other switches in
the fabric, and then local validation finds the error in the security database. This is a rare occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in
the ready state. If a switch is in the error state, the database may not be correctly updated for that
specific switch.
SEC-1076
Message
NoNodeWWNZoning option has been changed.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates the NoNodeWWNZoning option has been changed. If the option is turned on, a zone member
can be added using node WWNs, but the member will not be able to communicate with others nodes in
the zone.
Recommended
Action
Re-enable the current zone configuration for the change to take effect.
SEC-1077
Message
Failed to activate new policy set on all switches.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates the policy could not be activated. Possible reasons that the policy could not be activated
include not enough memory or a busy switch.
Recommended
Action
Run the secFabricShow command to verify that all switches in the fabric are in the ready state. Retry
the command when all switches are ready.