Cdr-1010, Cdr-1011, Cdr-1012 – Dell POWEREDGE M1000E User Manual
Page 232

210
Fabric OS Message Reference
53-1002749-01
CDR-1010
5
CDR-1010
Message
S
hardware, blade may need to be reset or replaced: fault1:0x
fault2:0x
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates that above-normal errors observed in hardware that may or may not impact the data traffic.
Recommended
Action
When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
slotPowerOn commands. If the problem persists, replace the blade.
CDR-1011
Message
S
ftx= tov=
vc_no=
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that one or more credits have been lost on a back-end port, and there is no traffic on that port
for two seconds.
Recommended
Action
Turn on the back-end credit recovery to reset the link and recover the lost credits. If credit recovery has
already been turned on, the link will be reset to recover the credits and no action is required.
CDR-1012
Message
S
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the specified port has failed. Port initialization will be retried.
Recommended
Action
Replace the SFP transceiver and the cable and then re-enable the port.