Ns messages, Ns-1001, Ns-1002 – Dell POWEREDGE M1000E User Manual
Page 651: Ns-1003

Fabric OS Message Reference
629
53-1002749-01
NS-1001
5
NS Messages
NS-1001
Message
The response for request 0x
larger than the max frame size the remote switch can support.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the response payload exceeds the maximum frame size the remote switch can handle.
Recommended
Action
Execute the firmwareDownload command to upgrade the remote switch with Fabric OS v4.3 or later, or
Fabric OS v3.2 or later, as appropriate for the switch type, so that it can support GMI to handle frame
fragmentation and reassembly.
You can also reduce the number of devices connected to the local switch.
NS-1002
Message
Remote switch 0x
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the local switch cannot interact with the remote switch because of incompatible or obsolete
firmware.
Recommended
Action
Execute the firmwareDownload command to upgrade the remote switch to the latest level of firmware.
NS-1003
Message
Number of local devices
support
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the Name Server on the standby control processor (CP) has a lower supported capability
than the active CP because of different firmware versions running on the active and standby CPs. This
means that the active and standby CPs are out of sync. Any execution of the haFailover or
firmwareDownload commands will be disruptive.