Auth-1035, Auth-1036 – Dell POWEREDGE M1000E User Manual
Page 176
![background image](/manuals/619985/176/background.png)
154
Fabric OS Message Reference
53-1002749-01
AUTH-1035
5
Recommended
Action
Reinitialize authentication using the portDisable and portEnable commands or the switchDisable and
switchEnable commands.
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
AUTH-1035
Message
Invalid length in
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that a particular data field in the authentication message has an invalid length field. This error
usually relates to internal failure. Usually this problem is transient. The authentication may fail.
Recommended
Action
Reinitialize authentication using the portDisable and portEnable commands or the switchDisable and
switchEnable commands.
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
AUTH-1036
Message
Invalid state
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the switch received an unexpected authentication message. Usually this problem is
transient. The authentication may fail.
Recommended
Action
Reinitialize authentication using the portDisable and portEnable commands or the switchDisable and
switchEnable commands.
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.