RCS-1010
5
RCS-1010
Message
Domain
E_Port(s) connected to this domain.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the specified remote domain is RCS-incapable, or the RCS-capable information could not
be retrieved for the specified remote domain due to some potential routing issues.
Recommended
Action
Run the rcsInfoShow command to view RCS capability of the switch.
Investigate for routing issue or check the cabling, and re-enable the disabled E_Ports to attempt another
exchange of RCS-capable information.
RCS-1011
Message
Remote domain
RCS-capable.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the specified remote domain is RCS-incapable, or the RCS-capable information could not
be retrieved for the specified remote domain due to some potential routing issues.
Recommended
Action
Run the rcsInfoShow command to view RCS capability of the switch.
Investigate for routing issue or check the cabling, and re-enable the disabled E_Ports to attempt another
exchange of RCS-capable information.
RCS-1012
Message
Local domain is RCS incapable (ForceDisabled is
Message Type
LOG | FFDC
Severity
WARNING
Probable Cause
Indicates that the specified domain is RCS-incapable.
Recommended
Action
Execute the supportSave command and contact your switch service provider.