Fabric OS Message Reference

687

53-1002749-01

SCN-1002

5

SCN-1002

Message

SCN queue overflow for process .

Message Type

FFDC | LOG

Severity

WARNING

Probable Cause

Indicates that an attempt to write a state change notification (SCN) message to a specific queue has
failed because the SCN queue for the specified daemon is full. This may be caused by the daemon
hanging or the system being busy.

The following are some of the valid values for the daemon name:

fabricd

asd

evmd

fcpd

webd

msd

nsd

psd

snmpd

zoned

fspfd

tsd

Recommended

Action

If this message is caused by the system being busy, the condition is temporary.

If this message is caused by a hung daemon, the software watchdog will cause the daemon to dump the
core and reboot the switch. In this case, execute the supportSave command to send the core files using
FTP to a secure server location.

If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.