Fabric OS Message Reference

175

53-1002749-01

BL-1034

5

BL-1034

Message

Slot FC Initialization completed.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the slot has completed initializing the Fibre Channel (FC) ports.

Recommended

Action

No action is required.

BL-1035

Message

Slot iSCSI port Initialization completed.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the slot has completed initializing the specified iSCSI port.

Recommended

Action

No action is required.

BL-1036

Message

Faulting 8G blade in slot = due to incompatible stag mode. All
EX/VEX ports must be disabled in order to enable the 8G blade in the chassis.

Message Type

LOG

Severity

CRITICAL

Probable Cause

Indicates that the 8 Gbps blade with legacy mode (EX_port having stag) will be disabled.

Recommended

Action

Disable all EX_Ports and VEX_Ports and execute the slotPowerOff or slotPowerOn commands on the
8 Gbps blade. All EX_Ports and VEX_Ports can be re-enabled.