Anv-1004, Anv-1005, Anv-1006 – Dell POWEREDGE M1000E User Manual
Page 163
Fabric OS Message Reference
141
53-1002749-01
ANV-1004
5
ANV-1004
Message
S
good_addr:0x
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may degrade
the data traffic.
Recommended
Action
Restart the system at the next maintenance window. If the problem persists, replace the blade.
ANV-1005
Message
S
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates memory allocation failure in the software.
Recommended
Action
Restart the system at the next maintenance window. If the problem persists, replace the switch or contact
your switch service provider.
ANV-1006
Message
S
Error =
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that renders the
chip as not operational.
Recommended
Action
Restart the system at the next maintenance window. If the problem persists, replace the blade.