Bl-1016, Bl-1017, Bl-1018 – Dell POWEREDGE M1000E User Manual
Page 191

Fabric OS Message Reference
169
53-1002749-01
BL-1016
5
BL-1016
Message
Blade port
Message Type
FFDC | LOG
Severity
CRITICAL
Probable Cause
Indicates that the specified blade port could not be enabled.
Recommended
Action
Make sure that the blade is seated correctly.
If the blade is seated correctly, execute the diagPost command to make sure that Power-On Self-Test
(POST) is enabled; then power cycle the blade using the slotPowerOff and slotPowerOn commands or
have the blade's ejector switch cycled to run POST and verify that the blade does not have any hardware
problems.
If the message persists, replace the blade.
BL-1017
Message
Slot
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the slot has started initializing the ports.
Recommended
Action
No action is required.
BL-1018
Message
Slot
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the slot has completed initializing the ports.
Recommended
Action
No action is required.