Conf-1024, Conf-1030, Conf-1031 – Dell POWEREDGE M1000E User Manual
Page 263

Fabric OS Message Reference
241
53-1002749-01
CONF-1024
5
CONF-1024
Message
configUpload failed
Message Type
LOG
Severity
INFO
Probable Cause
Indicates a configUpload operation has failed.
Recommended
Action
Execute the errShow command to view the error log. Correct the error and execute the configUpload
command again.
CONF-1030
Message
Configuration database full, data not committed (key:
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the previous configuration commands have resulted in a database full
condition.Configuration changes associated with the specified key was not applied.
Recommended
Action
Use configure command and various other commands to erase configuration parameters that are no
longer required. As a last resort, execute the configDefault command and reconfigure the system.
CONF-1031
Message
configDefault completed successfully
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the configDefault command was initiated and completed successfully.
Recommended
Action
No action is required.