Bl-1025, Bl-1026, Bl-1027 – Dell POWEREDGE M1000E User Manual
Page 194

172
Fabric OS Message Reference
53-1002749-01
BL-1025
5
BL-1025
Message
All GigE/FCIP/Virtualization/FC Fastwrite ports on the blade in slot
will be reset as part of the firmware upgrade.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that a recent firmware upgrade caused the blade's firmware to be upgraded and resulted in the
cold upgrade. As part of the upgrade, all the Gigabit Ethernet, Fibre Channel over IP (FCIP),
virtualization data elements, and FC Fastwrite ports were reset.
Recommended
Action
No action is required.
BL-1026
Message
Internal port offline during warm recovery, state
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates that an internal port went offline during warm recovery of the switch. The switch will reboot and
start cold recovery.
Recommended
Action
Execute the supportSave command and then reboot switch. If the problem persists, replace the switch.
BL-1027
Message
Blade in slot
boot status> 0x<1250 1 boot status>.
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates that the blade failed to boot properly.
Recommended
Action
Reboot or power cycle the blade using the slotPowerOff and slotPowerOn commands.