Fcr-1097, Fcr-1098 – Dell POWEREDGE M1000E User Manual
Page 395
![background image](/manuals/619985/395/background.png)
Fabric OS Message Reference
373
53-1002749-01
FCR-1097
5
FCR-1097
Message
Failed to get for
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the authentication process failed to get a particular authentication value at certain phase.
Data type is the payload or structure that failed to get memory.
Recommended
Action
Usually this problem is transient. The authentication may fail.
Reinitialize authentication using the portDisable and portEnable commands or the switchDisable and
switchEnable commands.
If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers;
then run the supportSave command and contact your switch service provider.
FCR-1098
Message
Invalid message code for
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates the receiving payload does not have valid message code for a particular authentication phase.
Recommended
Action
Usually this problem is transient. The authentication may fail.
Reinitialize authentication using the portDisable and portEnable commands or the switchDisable and
switchEnable commands.
If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers;
then run the supportSave command and contact your switch service provider.