beautypg.com

Auth-1032, Auth-1033, Auth-1034 – Dell POWEREDGE M1000E User Manual

Page 175

background image

Fabric OS Message Reference

153

53-1002749-01

AUTH-1032

5

Recommended

Action

Reset the secret value using the secAuthSecret command.

Reinitialize authentication using the portDisable and portEnable commands or the switchDisable and
switchEnable commands.

If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.

AUTH-1032

Message

Failed to generate for payload: length length>, error code , port .

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the authentication process failed to generate specific data (challenge, nonce, or response
data) for an authentication payload. This usually relates to internal failure.

A nonce is a single-use, usually random value used in authentication protocols to prevent replay attacks.

Usually this problem is transient. The authentication may fail.

Recommended

Action

Reinitialize authentication using the portDisable and portEnable commands or the switchDisable and
switchEnable commands.

If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.

AUTH-1033

Message

Disable port due to unauthorized switch .

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that an entity was not configured in the Switch Connection Control (SCC) policy and tried to
connect to the port.

Recommended

Action

Add World Wide Name (WWN) of the entity to the SCC policy and reinitialize authentication by using the
portDisable and portEnable commands or the switchDisable and switchEnable commands.

AUTH-1034

Message

Failed to validate name in : port number>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the specified entity name in the payload is not in the correct format.