Fabric OS Message Reference
53-1002749-01
NS-1004
5
Recommended
Action
To avoid disruption of traffic in the event of an unplanned failover, schedule a firmware download so that
the active and standby CPs have the same firmware version.
Reduce the local device count to follow the capability of the earliest version of firmware.
NS-1004
Message
Number of local devices
support
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the Name Server on the standby control processor (CP) has a lower supported capability
than the active CP because of different firmware versions running on the active and standby CPs. This
means that the active and standby CPs are out of sync. Any execution of the haFailover or
firmwareDownload commands will be disruptive.
Recommended
Action
To avoid disruption of traffic in the event of an unplanned failover, schedule a firmware download so that
the active and standby CPs have the same firmware version.
Reduce the local device count to follow the capability of the earliest version of firmware.
NS-1005
Message
Zone size of
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates the effective zone size has exceeded the limit that a remote switch can support. The oversized
portion will be truncated.
Recommended
Action
Reduce the zone size to 1024 or smaller, or upgrade the software of the remote switch to support 2048
zones.
NS-1006
Message
Duplicate WWN was detected with PID 0x
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that an existing device has the same World Wide Name (WWN) as that of a new device that
has come online.