Ssmd-1207, Ssmd-1208, Ssmd-1209 – Dell POWEREDGE M1000E User Manual
Page 837
Fabric OS Message Reference
815
53-1002749-01
SSMD-1207
5
SSMD-1207
Message
QoS failed programming interface 0x
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that DCE SSM encountered an unexpected error in programming the dataplane ASIC for
enforcing the interface Default CoS feature.
Recommended
Action
Delete and reapply the QoS interface Default CoS policy using the qos cos command.
If the problem persists, restart or power cycle the switch.
SSMD-1208
Message
QoS failed programming interface 0x
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that DCE SSM encountered an unexpected error in programming the dataplane ASIC for
enforcing the interface Trust feature.
Recommended
Action
Delete and reapply the QoS interface Trust policy using the qos trust cos command.
If the problem persists, restart or power cycle the switch.
SSMD-1209
Message
QoS failed programming interface 0x
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that DCE SSM encountered an unexpected error in programming the dataplane ASIC for
enforcing the interface CoS Mutation mapping feature.
Recommended
Action
Delete and reapply the QoS interface CoS Mutation policy using the qos cos-mutation command.
If the problem persists, restart or power cycle the switch.