Message
Primary LUN is restored from mirror LUN. LUN in read-only mode. Container:
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that a re-keyed primary LUN may have been restored from a mirror LUN without synchronizing.
Recommended
Action
Perform the following steps.
1. Create a new primary LUN.
2. Add the new primary LUN to its container with the
-newLUN
option.
3. Using host-based migration application, copy data from the old to the new primary LUN.
CVLC-1032
Message
Secondary metadata for LUN has been restored. Container:
Initiator:
Message Type
LOG
Severity
INFO
Probable Cause
Indicates the host I/Os to secondary metadata region.
Recommended
Action
No action is required.
CVLC-1033
Message
Rebalance completed for EE:
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that a rebalance operation was performed.
Recommended
Action