SYSC-1001
5
SYSC Messages
SYSC-1001
Message
Failed to run
Message Type
FFDC | LOG
Severity
CRITICAL
Probable Cause
Indicates that one of the programs would not run on the system during the boot sequence.
Recommended
Action
If the message is reported during a reboot after new firmware has been loaded, try reloading the
firmware using the firmwareDownload command.
If the message persists, there may be a conflict between the two versions of firmware or the nonvolatile
storage may be corrupted.
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
SYSC-1002
Message
Switch bring-up timed out.
Message Type
FFDC | LOG
Severity
CRITICAL
Probable Cause
Indicates that the system timed out during a reboot or failover sequence, waiting for one or more
programs to register with system services or to fail over to active status.
Recommended
Action
The switch is in an inconsistent state and can be corrected only by a reboot or power cycle. Before
rebooting the chassis, record the firmware version on the switch or control processor (CP) and run the
haDump command. If this is a dual-CP switch, gather the output from the CP in which this log message
appeared.
SYSC-1004
Message
Daemon
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that a terminated daemon is restarted by the system automatically.
Recommended
Action
Execute the supportSave command to gather troubleshooting data. No further action is required.