beautypg.com

Hil-1603, Hil-1605, Hil-1610 – Dell POWEREDGE M1000E User Manual

Page 584

background image

562

Fabric OS Message Reference

53-1002749-01

HIL-1603

5

HIL-1603

Message

fans out of service. System is shutting down immediately.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that the total fan failure count is greater than or equal to two.

Recommended

Action

To avoid causing damage to the switch, the system shuts down automatically. To help prevent future
problems, make sure that all the fans are working properly.

HIL-1605

Message

High temperature ( C), fan speed increasing per
environmental specifications.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that temperatures in the system have risen above the threshold and that the fan speed is being
increased.

Recommended

Action

No action is required.

HIL-1610

Message

Fan/PS unit not supplying power, fan speeds
may not be available. Please ensure that the unit has power and the switch is on.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the power supply is not connected to a power source, is not switched on, or the unit is
faulty. This message is applicable only to the Brocade 5100.

Recommended

Action

Ensure the power cord is connected to the unit with a valid power source and then switch on the unit. If
the problem persists, try reseating the unit. If the problem still persists, replace the FRU.