Fabric OS Message Reference
449
53-1002749-01
FW-1054
5
FW-1054
Message
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the value of the small form-factor pluggable (SFP) Power on Hours has risen above the
high boundary. The high value indicates the maximum lifetime use of the SFP.
Recommended
Action
Replace the SFP.
FW-1113
Message
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the number of times E_Ports have gone down has changed. E_Ports go down each time
you remove a cable or small form-factor pluggable (SFP). SFP failures also cause E_Ports to go down.
Down E_Port may be caused by transient errors.
Recommended
Action
Check both ends of the physical connection and verify that the SFPs and cables are functioning properly.
FW-1114
Message
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the number of times E_Ports have gone down has fallen below the low boundary. E_Ports
go down each time you remove a cable or small form-factor pluggable (SFP). SFP failures also cause
E_Ports to go down. Down E_Port may be caused by transient errors.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation. A low number of E_Port failures means that the switch is functioning normally.