beautypg.com

Xtun-1006, Xtun-1007, Xtun-1996 – Dell POWEREDGE M1000E User Manual

Page 903

background image

Fabric OS Message Reference

881

53-1002749-01

XTUN-1006

5

XTUN-1006

Message

FCIP FC frame drop due to transmit timeout on slot=7800)> DP= BLS=
DR= Frames Dropped=dropped>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that a Fibre Channel (FC) Send frame timeout occurred and the frames were dropped from the
SW queue.

Recommended

Action

This error indicates that there is a slow draining device or a hung Blaster TX Descriptor Ring.

XTUN-1007

Message

FCIP FC frame drop due to truncated receive on slot=7800)> DP= BLS=
DR= Frames Dropped=dropped>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that a Fibre Channel (FC) Received frame event was posted, but the frame was dropped due to
an invalid receive length. This error occurs only on faulty hardware.

Recommended

Action

Contact your vendor's customer support for assistance.

XTUN-1996

Message

FTRACE buffer on slot DP DP Number> has been cleared.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that a CLI command or supportSave operation freed the trace buffer back into the FTRACE
free pool.

Recommended

Action

No action is required.