Xtun-1006, Xtun-1007, Xtun-1996 – Dell POWEREDGE M1000E User Manual
Page 903

Fabric OS Message Reference
881
53-1002749-01
XTUN-1006
5
XTUN-1006
Message
FCIP FC frame drop due to transmit timeout on slot=
DR=
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that a Fibre Channel (FC) Send frame timeout occurred and the frames were dropped from the
SW queue.
Recommended
Action
This error indicates that there is a slow draining device or a hung Blaster TX Descriptor Ring.
XTUN-1007
Message
FCIP FC frame drop due to truncated receive on slot=
DR=
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that a Fibre Channel (FC) Received frame event was posted, but the frame was dropped due to
an invalid receive length. This error occurs only on faulty hardware.
Recommended
Action
Contact your vendor's customer support for assistance.
XTUN-1996
Message
FTRACE buffer
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that a CLI command or supportSave operation freed the trace buffer back into the FTRACE
free pool.
Recommended
Action
No action is required.