FW-1051
5
FW-1051
Message
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the value of the small form-factor pluggable (SFP) voltage has risen above the high
boundary. High voltages indicate possible hardware failures.
Recommended
Action
Frequent voltage fluctuations indicate that the SFP is deteriorating. Replace the SFP.
FW-1052
Message
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the value of the small form-factor pluggable (SFP) voltage has changed from a value
outside of the acceptable range to a value within the acceptable range.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation.
FW-1053
Message
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the value of the small form-factor pluggable (SFP) Power on Hours has fallen below the
low boundary.
Recommended
Action
Configure the low threshold to 1 so that the threshold triggers an alarm when the value falls to 0