Bl-1031, Bl-1032, Bl-1033 – Dell POWEREDGE M1000E User Manual
Page 196
![background image](/manuals/619985/196/background.png)
174
Fabric OS Message Reference
53-1002749-01
BL-1031
5
BL-1031
Message
Link timeout in internal port (slot
blade fault. Use slotpoweroff/slotpoweron to recover the blade.
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates that link timeout occurred in one of the back-end internal ports.
Recommended
Action
Power cycle the blade using the slotPowerOff and slotPowerOn commands.
BL-1032
Message
(slot
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates that back-end (non-user) ports have not come online within the time limit.
Recommended
Action
Execute the diagPost command to make sure that Power-On Self-Test (POST) is enabled; then power
cycle the blade using the slotPowerOff and slotPowerOn commands or have the blade's ejector switch
cycled to run POST and verify that the blade does not have any hardware problems.
If the message persists, replace the blade.
BL-1033
Message
(slot
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates that the system has timed out waiting for the disable messages from the user ports after
disabling the ports.
Recommended
Action
Execute the diagPost command to make sure that Power-On Self-Test (POST) is enabled; then power
cycle the blade using the slotPowerOff and slotPowerOn commands or have the blade's ejector switch
cycled to run POST and verify that the blade does not have any hardware problems.