Fabric OS Message Reference

777

53-1002749-01

SPC-1001

5

SPC Messages

SPC-1001

Message

S, Cryptographic operation enabled.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the cryptographic operation is enabled on an encryption engine.

Recommended

Action

No action is required.

SPC-1002

Message

S, Cryptographic operation disabled.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the cryptographic operation is disabled on an encryption engine.

Recommended

Action

No action is required.

SPC-1003

Message

S, Security Processor faulted.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the security processor is faulted because of an internal error. Cryptographic operations are
affected.

Recommended

Action

To recover a bladed system, execute the slotPowerOff and slotPowerOn commands on the blade. To
recover a non-bladed system, execute the fastboot command on the switch.