Esw messages, Esw-1001, Esw-1002 – Dell POWEREDGE M1000E User Manual
Page 322: Esw-1003

300
Fabric OS Message Reference
53-1002749-01
ESW-1001
5
ESW Messages
ESW-1001
Message
Switch is not in ready state - Switch enable failed, switch status= 0x
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the switch enable operation has failed.
Recommended
Action
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
ESW-1002
Message
Security violation: Unauthorized device
port
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the specified device is not present in the authorized profile list.
Recommended
Action
Verify that the device is authorized to log in to the switch. If the device is authorized, execute the
secPolicyDump command to verify whether the World Wide Name (WWN) of the specified device is
listed. If it is not listed, execute the secPolicyAdd command to add this device to an existing policy.
ESW-1003
Message
Slot ENABLED but Not Ready during recovery, disabling slot =
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the slot state has been detected as inconsistent during failover or recovery.
Recommended
Action
For a bladed switch, execute the slotPowerOff and slotPowerOn commands to power cycle the blade.
For a non-bladed switch, restart or power cycle the switch.