Fabr-1035, Fabr-1036, Fabr-1037 – Dell POWEREDGE M1000E User Manual
Page 336
314
Fabric OS Message Reference
53-1002749-01
FABR-1035
5
FABR-1035
Message
Slave area does not match Master
port
Message Type
LOG
Severity
INFO
Probable Cause
Indicates the Slave port's Trunk Area differs from that of the Master port.
Recommended
Action
Move the cable to a port to match with the same Master Trunk Area, or disable Trunk Area. You must
manually enable the port or the port remains disabled forever.
Refer to the Fabric OS Administrator's Guide for more information.
FABR-1036
Message
F_Port trunks are only allowed on Trunk Area enabled port. Persistently disabling
port
Message Type
LOG
Severity
INFO
Probable Cause
Indicates the specified port is being disabled because when the port on a switch is Trunk Area-enabled, it
does not allow other devices like Access Gateway (AG) or HBA that are not Trunk Area-enabled.
Recommended
Action
Move the cable to a port that does not have Trunk Area enabled.
FABR-1037
Message
Port configuration incompatible with Trunk Area enabled port. Persistently
disabling port
Message Type
LOG
Severity
INFO
Probable Cause
Indicates the specified port is being disabled because when the port attempts to go online, the switch
finds the Trunk Area enabled is incompatible with port configurations such as long distance, port mirror,
fast write, or EX_Port.
Recommended
Action
Check the port configurations to disable long distance, port mirror, fast write, or EX_Port.