beautypg.com

Ss-1009, Ss-1010, Ss-1011 – Dell POWEREDGE M1000E User Manual

Page 830

background image

808

Fabric OS Message Reference

53-1002749-01

SS-1009

5

SS-1009

Message

supportsave failed. Reason:No ISC
connection for .

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that there is no Inter-Subsystem Communication (ISC) connection for the specified node slot.

Recommended

Action

Restart the switch using the reboot command and then execute the supportSave command.

SS-1010

Message

CORE/FFDC files have been uploaded to the host with IP address .

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the supportSave command was used to transfer core and first failure data capture (FFDC)
files to a remote location.

Recommended

Action

No action is required.

SS-1011

Message

CORE/FFDC files have been transferred to the USB storage device.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the supportSave command was used to transfer core and first failure data capture (FFDC)
files to a USB storage Device.

Recommended

Action

No action is required.