beautypg.com

Fw-1197, Fw-1198, Fw-1199 – Dell POWEREDGE M1000E User Manual

Page 494

background image

472

Fabric OS Message Reference

53-1002749-01

FW-1197

5

FW-1197

Message

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the number of link resets that the port experiences has fallen below the low boundary level.
Link resets occur due to link timeout errors that indicate no frame activity. A low number of link resets
means that the switch is functioning normally.

Recommended

Action

Respond to this message as is appropriate to the particular policy of the end-user installation.

FW-1198

Message

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the number of link resets that the port experiences has increased above the high boundary
level. Link resets occur due to link timeout errors that indicate no frame activity. Both physical and
hardware problems can cause link resets to increase.

Recommended

Action

Check both ends of your cable connection. Verify if the cable and small form-factor pluggables (SFPs)
are faulty.

FW-1199

Message

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the number of link resets that the port experiences has changed from a value beyond the
acceptable range to a value within the acceptable range. Link resets occur due to link timeout errors that
indicate no frame activity. Both physical and hardware problems can cause link resets to increase.

Recommended

Action

Respond to this message as is appropriate to the particular policy of the end-user installation.