Anv messages, Anv-1001, Anv-1002 – Dell POWEREDGE M1000E User Manual
Page 162: Anv-1003

140
Fabric OS Message Reference
53-1002749-01
ANV-1001
5
ANV Messages
ANV-1001
Message
Port
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates a deteriorated small form-factor pluggable (SFP) transceiver, an incompatible SFP transceiver
pair, or a faulty cable between the peer ports.
Recommended
Action
Verify that compatible SFP transceivers are used on the peer ports, the SFP transceivers have not
deteriorated, and the Fibre Channel cable is not faulty. Replace the SFP transceivers or the cable, if
necessary.
ANV-1002
Message
Port
Message Type
LOG | FFDC
Severity
ERROR
Probable Cause
Indicates an internal error. All the ports on the chip will be disrupted.
Recommended
Action
To recover a bladed system, execute the slotPowerOff and slotPowerOn commands on the blade. To
recover a non-bladed system, execute the fastBoot command on the switch.
ANV-1003
Message
S
Error =
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may degrade
the data traffic.