beautypg.com

C2 messages, C2-1001, C2-1002 – Dell POWEREDGE M1000E User Manual

Page 209: C2-1004

background image

Fabric OS Message Reference

187

53-1002749-01

C2-1001

5

C2 Messages

C2-1001

Message

Port port faulted due to SFP validation failure. Check if the SFP is
valid for the configuration.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates a deteriorated small form-factor pluggable (SFP) transceiver, an incompatible SFP transceiver
pair, or a faulty cable between the peer ports.

Recommended

Action

Verify that compatible SFP transceivers are used on the peer ports, the SFP transceivers have not
deteriorated, and the Fibre Channel cable is not faulty. Replace the SFP transceivers or the cable if
necessary.

C2-1002

Message

Port chip faulted due to an internal error.

Message Type

LOG | FFDC

Severity

ERROR

Probable Cause

Indicates an internal error. All the ports on the blade or switch will be disrupted.

Recommended

Action

To recover a bladed system, execute the slotPowerOff and slotPowerOn commands on the blade. To
recover a non-bladed system, execute the fastBoot command on the switch.

C2-1004

Message

S,C: Invalid DMA ch pointer, chan:,
good_addr:0x bad_addr:0x.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may degrade
the data traffic.

Recommended

Action

Restart the system at the next maintenance window. If the problem persists, replace the blade.