Em-1044, Em-1045, Em-1046 – Dell POWEREDGE M1000E User Manual
Page 310
288
Fabric OS Message Reference
53-1002749-01
EM-1044
5
EM-1044
Message
Can't power on
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the specified field-replaceable unit (FRU) cannot be powered on because the associated
logical switch is shutdown.
Recommended
Action
Execute the switchStart command on the associated logical switch.
EM-1045
Message
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that an automatic power adjustment is being made because of the (predicted) failure of a power
supply or the insertion or removal of a port blade. The new state value can be one of the following values:
•
On - A port blade is being powered on because the power is available (a power supply was
inserted or a port blade was removed or powered down).
•
Off - A port blade has been powered down because of the (predicted) failure of the power
supply.
•
Down - A newly inserted port blade was not powered on because there was not enough power
available.
Recommended
Action
The Brocade 24000 requires only a single power supply for a fully populated chassis; however, you must
always operate the system with at least two power supplies for redundancy.
EM-1046
Message
Error status received for blade ID
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the specified blade is incompatible.