Fabric OS Message Reference

53-1002749-01

FW-1514

5

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation.

FW-1514

Message

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the number of synchronization losses that the port experiences has changed and dropped
below the upper threshold boundary to a value within the acceptable range. Loss of synchronization
errors frequently occur due to a faulty small form-factor pluggable (SFP) or cable. Signal losses often
create synchronization losses.

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation.

FW-1515

Message

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the number of signal losses that the port experiences has changed and crossed the lower
threshold boundary to a value within the acceptable range. Loss of signal generally indicates a physical
problem.

Recommended

Action

Frequent loss of signal generally indicates a physical problem. Check both ends of your cable
connection. Verify that the cable and small form-factor pluggables (SFPs) are not faulty.

FW-1516

Message

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the number of signal losses that the port experiences has changed and dropped below the
upper threshold boundary to a value within the acceptable range. Loss of signal generally indicates a
physical problem.

Recommended

Action

Frequent loss of signal generally indicates a physical problem. Check both ends of your cable
connection. Verify that the cable and small form-factor pluggables (SFPs) are not faulty.