Pdm messages, Pdm-1001, Pdm-1002 – Dell POWEREDGE M1000E User Manual
Page 664: Pdm-1003
642
Fabric OS Message Reference
53-1002749-01
PDM-1001
5
PDM Messages
PDM-1001
Message
Failed to parse the pdm config.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the Parity Data Manager (PDM) process could not parse the configuration file. This may be
caused by a missing configuration file during the installation.
Recommended
Action
Execute the firmwareDownload command to reinstall the firmware.
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
PDM-1002
Message
ipcInit failed.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the Parity Data Manager (PDM) process could not initialize the inter-process
communication (IPC) mechanism.
Recommended
Action
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
PDM-1003
Message
pdm [-d] -S
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that a syntax error occurred when trying to launch the Parity Data Manager (PDM) process.
Recommended
Action
Execute the firmwareDownload command to reinstall the firmware.
If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.