beautypg.com

Pdm messages, Pdm-1001, Pdm-1002 – Dell POWEREDGE M1000E User Manual

Page 664: Pdm-1003

background image

642

Fabric OS Message Reference

53-1002749-01

PDM-1001

5

PDM Messages

PDM-1001

Message

Failed to parse the pdm config.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the Parity Data Manager (PDM) process could not parse the configuration file. This may be
caused by a missing configuration file during the installation.

Recommended

Action

Execute the firmwareDownload command to reinstall the firmware.

If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.

PDM-1002

Message

ipcInit failed.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the Parity Data Manager (PDM) process could not initialize the inter-process
communication (IPC) mechanism.

Recommended

Action

If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.

PDM-1003

Message

pdm [-d] -S -s .

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that a syntax error occurred when trying to launch the Parity Data Manager (PDM) process.

Recommended

Action

Execute the firmwareDownload command to reinstall the firmware.

If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.