beautypg.com

Hil messages, Hil-1101, Hil-1102 – Dell POWEREDGE M1000E User Manual

Page 570: Hil-1103

background image

548

Fabric OS Message Reference

53-1002749-01

HIL-1101

5

HIL Messages

HIL-1101

Message

Slot faulted, () is above
threshold.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the blade voltage is above threshold.

Recommended

Action

Replace the faulty blade or switch (for non-bladed switches).

HIL-1102

Message

Slot faulted, () is below
threshold.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the blade voltage is below threshold.

Recommended

Action

Replace the faulty blade or switch (for non-bladed switches).

HIL-1103

Message

Blower faulted, () is above
threshold.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the fan voltage is above threshold.

Recommended

Action

Run the psShow command to verify the power supply status.

Try to reseat the faulty fan field-replaceable units (FRUs) and power supply FRU to verify that they are
seated properly.

If the problem persists, replace the fan FRU or the power supply FRU as necessary.