SEC-1173
5
SEC-1173
Message
Lost contact with Primary FCS switch.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates the switch has lost contact with the primary fabric configuration server (FCS) switch in the
secure fabric. This could result from the primary FCS being disabled.
Recommended
Action
If the primary FCS was disabled intentionally, no action is required; if not, check the primary FCS.
SEC-1174
Message
Failed to set
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates the fabric configuration server (FCS) or non-FCS password could not be set.
Recommended
Action
Verify all switches in the fabric are in time synchronization with the primary FCS and that no external
entity is trying to access the fabric. When verification is complete, retry the operation.
SEC-1175
Message
Failed to install zone data.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates the zone database could not be installed on the switch.
Recommended
Action
Verify all switches in the fabric are in time synchronization with the primary FCS and that no external
entity is trying to access the fabric. When verification is complete, retry the operation.