Fabric OS Message Reference
811
53-1002749-01
SSMD-1004
5
SSMD-1004
Message
Failed to unlock semaphore mutex: (
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the specified function failed to unlock the mutex (semaphore).
Recommended
Action
Restart or power cycle the switch.
SSMD-1005
Message
SSM start up failed.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that Data Center Ethernet (DCE) SSM encountered an unexpected severe error during basic
startup and initialization.
Recommended
Action
Restart or power cycle the switch.
If the problem persists, download a new firmware using the firmwareDownload command.
SSMD-1006
Message
Error while configuring ACL
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that an error occurred while programming a Ternary Content Addressable Memory (TCAM)
entry on the specified interface.
Recommended
Action
Try again after some time. If the problem persists, execute the supportSave command and then restart
or power cycle the switch.