Fabric OS Message Reference

53-1002749-01

FCR-1075

5

FCR-1075

Message

Zone Name configuration is larger than characters in the edge
fabric connected to port .

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the zone name configuration size created in the connected fabric exceeds the maximum
supported by the FC Router. This size is equal to the total number of characters used by all the zone
names in the edge fabric zoning database.

The limit includes both LSAN and non-LSAN zone names defined in the zoning name database of the
edge fabric.

Recommended

Action

Limit the zone configuration size in the edge fabric connected to this port by either reducing the number
of zones or changing the zone names to smaller names.

FCR-1076

Message

Port disabled, system only supports front domains.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the maximum number of supported front domains was exceeded. To enable the specified
port, disable any other operational front domain and then re-enable the port.

Recommended

Action

Make sure to remain within the maximum number of supported front domains.

FCR-1077

Message

Port rejected fabric binding request/check from the M-Model switch;
.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that an M-Model edge switch attempted to either activate or check the fabric binding. This port
will be disabled if this event occurred during a check of fabric binding and not during failure to activate
fabric binding. The error is caused when the binding list details configured on the M-Model switch do not
match with the currently configured front port domain ID and WWN of the EX_Port on which this
operation was attempted.

Recommended

Action

Ensure that the M-Model switch has the same currently configured details such as the front port domain
ID and WWN of the EX_Port on which this operation was attempted.