Bl-1022, Bl-1023, Bl-1024 – Dell POWEREDGE M1000E User Manual
Page 193

Fabric OS Message Reference
171
53-1002749-01
BL-1022
5
BL-1022
Message
Init Failed: Switch DISABLED because internal ports were not ONLINE, internal port number not ONLINE>.
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates that the switch initiation failed because one or more of the internal ports was not online. The
switch is faulted.
Recommended
Action
Reboot or power cycle the switch.
Additional fault messages precede and follow this error providing more information. Refer to other error
messages for recommended action.
If the message persists, replace the switch.
BL-1023
Message
Blade in slot
blade is faulted.
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates that the blade was reset before the initialization completed.
Recommended
Action
Reboot or power cycle the blade using the slotPowerOff and slotPowerOn commands.
If the message persists, replace the blade.
BL-1024
Message
All ports on the blade in slot
upgrade.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that a recent firmware upgrade caused the blade firmware to be upgraded and resulted in the
cold upgrade. As part of the upgrade, all datapath elements were reset.
Recommended
Action
No action is required.