beautypg.com

Fw-1247, Fw-1248, Fw-1249 – Dell POWEREDGE M1000E User Manual

Page 502

background image

480

Fabric OS Message Reference

53-1002749-01

FW-1247

5

FW-1247

Message

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the number of end-to-end word frames that the switch receives has changed from a value
outside of the acceptable range to a value within the acceptable range. Receive performance messages
appear due to the number of word frames that travel from the configured S_ID to the D_ID pair.

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation.

FW-1248

Message

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the number of end-to-end word frames that the switch transmits has changed. Transmit
performance messages appear due to the number of word frames that travel from the configured S_ID to
the D_ID pair.

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation.

FW-1249

Message

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the number of end-to-end word frames that the switch transmits has fallen below the low
boundary. Transmit performance messages appear due to the number of word frames that travel from
the configured S_ID to the D_ID pair.

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation.