296

Fabric OS Message Reference

53-1002749-01

EM-2003

5

EM-2003

Message

has failed the POST tests. FRU is being
faulted.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that a field-replaceable unit (FRU) has failed the Power-On Self-Test (POST). Refer to the
/tmp/post[1/2].slot#.log file for more information on the faults. To view this log file, you must be logged in
at the root level. The ID will be Switch for non-bladed systems.

Recommended

Action

On bladed systems, reseat the specified FRU.

On non-bladed switches, restart or power cycle the switch.

If the problem persists, perform the following actions:

Execute the

diagPost

command to make sure that Power-On Self-Test (POST) is enabled; then

power cycle the blade by using the

slotPowerOff

and

slotPowerOn

commands or have the

blade's ejector switch cycled to run POST and verify that the blade does not have any hardware
problems.

On bladed systems, replace the specified FRU; otherwise, replace the switch.