beautypg.com

Cvlc-1028, Cvlc-1029, Cvlc-1030 – Dell POWEREDGE M1000E User Manual

Page 276

background image

254

Fabric OS Message Reference

53-1002749-01

CVLC-1028

5

CVLC-1028

Message

Not starting auto rekey on LUN with uncompressible blocks 1-16. Container: container name>, Initiator: , LUN ID: .

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates a warning event.

Recommended

Action

Perform a manual re-key on this LUN.

CVLC-1029

Message

Mirror LUN is disabled as primary LUN is being rekeyed without splitting the
mirror. Container: , Initiator: ,
LUN ID: .

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that performing first-time encryption or manual re-key of primary LUN without splitting the
mirror.

Recommended

Action

Break the mirror and re-establish the mirror after re-key on primary LUN is complete.

CVLC-1030

Message

Primary LUN may be out of sync with mirror LUN. Container: name>, Initiator: , LUN ID: .

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates the manual re-key was completed on primary LUN.

Recommended

Action

Perform the following steps.

1. Make the target ports of the mirror LUN offline to hosts.

2. Re-establish the mirror.

3. After the mirror is in sync, split the mirror.

4. Bring back the target ports of the mirror LUN online.