CVLC-1028
5
CVLC-1028
Message
Not starting auto rekey on LUN with uncompressible blocks 1-16. Container:
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates a warning event.
Recommended
Action
Perform a manual re-key on this LUN.
CVLC-1029
Message
Mirror LUN is disabled as primary LUN is being rekeyed without splitting the
mirror. Container:
LUN ID:
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that performing first-time encryption or manual re-key of primary LUN without splitting the
mirror.
Recommended
Action
Break the mirror and re-establish the mirror after re-key on primary LUN is complete.
CVLC-1030
Message
Primary LUN may be out of sync with mirror LUN. Container:
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates the manual re-key was completed on primary LUN.
Recommended
Action
Perform the following steps.
1. Make the target ports of the mirror LUN offline to hosts.
2. Re-establish the mirror.
3. After the mirror is in sync, split the mirror.
4. Bring back the target ports of the mirror LUN online.