Swch-1019, Swch-1020, Swch-1021 – Dell POWEREDGE M1000E User Manual
Page 871
Fabric OS Message Reference
849
53-1002749-01
SWCH-1019
5
SWCH-1019
Message
Device
on device and port
Message Type
LOG
Severity
INFO
Probable Cause
Indicates a WWN-PID and port address binding collision.
Recommended
Action
The persistent PID is set on the device and the requested area cannot be assigned because the port it is
trying to log in through has a different area bound to it. Remove the WWN-PID binding using the
wwnaddress --unbind command or remove the port address binding using the portaddress --unbind
command and then re-enable the port.
SWCH-1020
Message
HA state out of sync: Standby CP (ver =
QoS links to AG(Active CP version =
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the standby control processor (CP) does not support links to Access Gateway running
quality of service (QoS).
Recommended
Action
Load a firmware version on the standby CP that supports QoS links to Access Gateway by using the
firmwareDownload command.
SWCH-1021
Message
HA state out of sync: Standby CP (ver =
Dynamic area on default switch (Active CP version =
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the standby control processor (CP) does not support dynamic area on the default switch.
Recommended
Action
Load a firmware version on the standby CP that supports dynamic area on the default switch by using the
firmwareDownload command.