Ns-1007, Ns-1008, Ns-1009 – Dell POWEREDGE M1000E User Manual
Page 653
Fabric OS Message Reference
631
53-1002749-01
NS-1007
5
Recommended
Action
The switch will process the new process ID (PID) and leave the existing PID intact. Subsequent switch
operations will clean up the obsolete PID. However, it is recommended that administrators remove
devices with a duplicate WWN.
NS-1007
Message
NS has detected a logical ISL port
fabric
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that a logical inter-switch link (LISL) is detected in a traffic isolation (TI) zone.
Recommended
Action
Remove the LISL port from the TI zone because the routing may not be set up correctly.
NS-1008
Message
Open FR license not installed.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that Open FR license is not installed and therefore local devices involved in Open FR will not
function.
Recommended
Action
Install the Open FR license or relocate Open FR devices to a licensed switch.
NS-1009
Message
NS has detected a device with Node WWN as zero, pid 0x
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that a device has logged in with node World Wide Node Name (WWNN) as zero. Brocade
Network Advisor (BNA) will not show the port connectivity.
Recommended
Action
Check the device that logged in. The device could be faulty.