Fabric OS Message Reference

631

53-1002749-01

NS-1007

5

Recommended

Action

The switch will process the new process ID (PID) and leave the existing PID intact. Subsequent switch
operations will clean up the obsolete PID. However, it is recommended that administrators remove
devices with a duplicate WWN.

NS-1007

Message

NS has detected a logical ISL port in TI zone in
fabric . Routing may not be setup correctly.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that a logical inter-switch link (LISL) is detected in a traffic isolation (TI) zone.

Recommended

Action

Remove the LISL port from the TI zone because the routing may not be set up correctly.

NS-1008

Message

Open FR license not installed.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that Open FR license is not installed and therefore local devices involved in Open FR will not
function.

Recommended

Action

Install the Open FR license or relocate Open FR devices to a licensed switch.

NS-1009

Message

NS has detected a device with Node WWN as zero, pid 0x.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that a device has logged in with node World Wide Node Name (WWNN) as zero. Brocade
Network Advisor (BNA) will not show the port connectivity.

Recommended

Action

Check the device that logged in. The device could be faulty.