Fabric OS Message Reference

53-1002749-01

CVLC-1034

5

CVLC-1034

Message

Rekey failed on Container: , Initiator: WWN>, LUN ID: because .

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the first-time encryption, key expired, or manual re-key operation failed.

Recommended

Action

No action is required.

CVLC-1035

Message

A decommissioned LUN has been added back as encrypted LUN. Container: container name>, Initiator: , LUN ID: .

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that a decommissioned LUN has been added as an encrypted LUN.

Recommended

Action

Perform the following steps.

1. Remove the LUN from the container.

2. Add the LUN back as a cleartext LUN.

3. Modify the LUN policy to encrypt.

CVLC-1039

Message

Refresh DEK operation . Container: container name>, Initiator: , LUN ID: .

Message Type

LOG

Severity

INFO

Probable Cause

Indicates the status of the refresh DEK operation.

Recommended

Action

No action is required.