Fw-1045, Fw-1046, Fw-1047 – Dell POWEREDGE M1000E User Manual
Page 468

446
Fabric OS Message Reference
53-1002749-01
FW-1045
5
FW-1045
Message
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the value of the small form-factor pluggable (SFP) voltage has changed. If the supplied
voltage of the SFP transceiver is outside of the normal range, this may indicate a hardware failure.
Recommended
Action
No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation. If the message persists, replace the SFP.
FW-1046
Message
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the value of the small form-factor pluggable (SFP) voltage has fallen below the low
boundary.
Recommended
Action
Verify that your optical components are clean and function properly. Replace deteriorating cables or
SFPs. Check for damage from heat or age.
FW-1047
Message
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the value of the small form-factor pluggable (SFP) voltage has risen above the high
boundary.
Recommended
Action
The supplied current of the SFP transceiver is outside of the normal range, indicating possible hardware
failure. If the current rises above the high boundary, you must replace the SFP.