Fw-1313, Fw-1314, Fw-1315 – Dell POWEREDGE M1000E User Manual
Page 511

Fabric OS Message Reference
489
53-1002749-01
FW-1313
5
FW-1313
Message
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the number of write SNMP (WSNMP) violations has fallen below the low boundary.
WSNMP violations indicate that an SNMP "get/set" operation request has been received from an
unauthorized IP address.
Recommended
Action
No action is required.
FW-1314
Message
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the number of write SNMP (WSNMP) violations has risen above the high boundary.
WSNMP violations indicate that an SNMP "get/set" operation request has been received from an
unauthorized IP address.
Recommended
Action
Execute the errShow command to determine the IP address that sent the request. Responses to
security-class messages depend on user policies. Consult your security administrator for response
strategies and policies.
FW-1315
Message
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the number of write SNMP (WSNMP) violations has changed from a value outside of the
acceptable range to a value within the acceptable range. WSNMP violations indicate that an SNMP
"get/set" operation request has been received from an unauthorized IP address.
Recommended
Action